Home > Product information > Body-washing showers for pools safety hot water supply units
Body-washing showers for pools

*Schematic drawings may be viewed after completing the membership registration.
[Click here to register as a member.]

safety hot water supply units

*1: If the pipe between the safety optimal-temperature hot water supply unit and the body-washing shower is long, the system may initially discharge cold water or take some time before any water is discharged when the shower is turned on.
To prevent such a situation, be sure to install the optimal-temperature water supply unit near the shower.
*Install the optimal-temperature water supply unit and the control panel below the ceiling at a height that does not interfere with the temperature control operation or maintenance work.
Do not install the products above the ceiling or where maintenance would be difficult to perform.
*3: Choose the push-button switch and the mode selector switch according to your needs.
*To view the list of available showerheads, click here.

Youtube←Introductory video on the body-washing shower system for pools
(two-way passage type) (Japanese only)
http://youtu.be/GhfThO4BWt0

Safety optimal-temperature water replenishment unit

Hot water + Water

Model Aperture (A) Flow/0.2 MPa Minimum required flow *2
XLF-25×32SCV 25×25×32 115ℓ/min 10ℓ/min
XLF-32×32SCV 32×32×32 130ℓ/min 12ℓ/min
E2F-40×40SCV 40×40×40 237ℓ/min None

*1: A separate order must be made for master valves that come above the unit.
*2: The minimum required flow means the amount of flow below which the temperature control function cannot operate properly.
*3: The back plate is an option.
*Indoor installation type.
*When installing the unit, be sure to leave enough space around it for maintenance purposes.

Safety optimal-temperature water replenishment unit
(JWWA-certified product)

Hot water + Water

Model Aperture (A) Flow/0.2 MPa Minimum required flow *2
XLFN-25×32SCV 25×25×32 115ℓ/min 10ℓ/min
XLFN-32×32SCV 32×32×32 130ℓ/min 12ℓ/min

*1: A separate order must be made for master valves that come above the unit.
*2: The minimum required flow means the amount of flow below which the temperature control function cannot operate properly.
*3: The back plate is an option.
*Indoor installation type.
*When installing the unit, be sure to leave enough space around it for maintenance purposes.

Safety sensor valve

Model Aperture (A) Opening/closing speed (in seconds)
Union connection Flange connection    
SCV-15DC - 15 1~2
SCV-20DC - 20 1~2
SCV-25DC - 25 1~2
SCV-32DC SCV-32FDC 32 2~3
- SCV-40FDC 40 2~3
- SCV-50FDC 50 4~6

*The temperature sensor (pt-100 Ω) for the exit side is included.
*Indoor installation type.